(N)TMCWOEU
Flexible cable connections TENAX®-TRAIN-Plus (N)TMCWOEU
Использование
Flexible medium voltage single-core cable are generally used in short lengths, e.g. to connect switch cells or mobile transformer stations to the overhead line. They can also be used to connect current collectors in locomotives and trains. During installation and operation, they should be protected against major mechanical stresses. In addition, the general specifications in DIN VDE 0298-3 apply. Can be used in rail vehicles with hazard level HL3 according to DIN EN 45545-1(2013).
Конструкция
| Customs Tariff Number (code number) |
85446010900000000
|
| Standard |
DIN VDE 0250-813 (with ref. to)
|
| Conductor material |
tinned copper
|
| Conductor construction |
Class 5 = flexible
|
| Insulation |
HEPR
|
| Electrical field control |
inner and outer semiconducting layer (triple extrusion)
|
| Screen |
tinned copper braid
|
| Sheathing material |
cross-linked elastomer EM 104
|
| Colour of outer sheath |
red
|
| Flame-retardant |
VDE 0482-266-2-4/IEC 60332-3-24 (Cat. C)
|
| Halogen-free |
yes
|
| UV-resistant |
yes
|
| Oil-resistant |
EN 60811-404
|
| Ozone-resistant |
DIN EN 60811-2-1(A)
|
| Max. temperature at conductor, °C |
90 °C
|
| Max. short circuit temperature at conductor, °C |
250 °C
|
| Permitted outer cable temperature, fixed, °C |
-40 - +80 °C
|
| Permitted outer cable temperature, moved, °C |
-40 - +80 °C
|
| Bending radius, fixed installation |
6 x Ø
|
| Bending radius, moving application |
10 x Ø
|
| Number of cores |
1
|
| metal base Cu |
150 EUR/100 kg
|
| Unit of measurement |
metre
|
Стандарты
Flexible medium voltage single-core cable are generally used in short lengths, e.g. to connect switch cells or mobile transformer stations to the overhead line. They can also be used to connect current collectors in locomotives and trains. During installation and operation, they should be protected against major mechanical stresses. In addition, the general specifications in DIN VDE 0298-3 apply. Can be used in rail vehicles with hazard level HL3 according to DIN EN 45545-1(2013).
| Артикул |
Типоразмер кабеля |
| 051365 |
1X95/16 26/45 kV RD |
| 051516 |
1X400/35 26/45 kV RD |
| 051518 |
1X50/16 26/45 kV RD |
| 051520 |
1X240/25 26/45 kV RD |
| 051750 |
1X70/16 26/45 kV BK |
| 051804 |
1X120/25 26/45 kV RD |
| 051805 |
1X120/16 26/45 kV RD |
| 052056 |
1X185/25 26/45 kV RD |
| 052129 |
1X150/25 26/45 kV RD |
| 054798 |
TENAX-TRAIN-PLUS (N)TMCWOEU 1X240/25 26/45KV BK |
| 054820 |
TENAX-TRAIN-PLUS (N)TMCWOEU 1X500/35 26/45KV RD |
| 054927 |
TENAX-TRAIN-PLUS (N)TMCWOEU 1X150/25 26/45KV BK |