(N)HXH FE180/E90
FRNC power cable (N)HXH FE180/E90
Использование
For installation in dry and wet rooms, also for direct bedding in concrete, but not for direct burial in the ground and not for use in water. The cable has improved properties in case of fire and may be used in public buildings with high safety requirements. The cable is halogen-free, has a low smoke density and is fire-resistant according to VDE 0472 part 814 (180 min., = IEC 60331), EN 50200 and EN 50362. Furthermore the cable passed the test of 90 min. circuit integrity according to DIN 4102 part 12 (E 90) for all so-called standard installation systems (ladder, tray and ceiling). A special test certificate about the circuit integrity is issued by -The Civil Engineering Materials Testing Institute-. For calculation of electrical systems with circuit integrity has to be considered that electrical resistance of copper conductors at 1000 °C is approximately 4,5 times higher than at 20 °C and the current carrying capacity has to be reduced respectively.
Конструкция
| Customs Tariff Number (code number) |
85444995900000000
|
| Standard |
VDE 0266
|
| Conductor material |
copper, bare
|
| Conductor construction |
class 1, from 25 sqmm class 2
|
| Insulation |
FRNC-compound HI1
|
| Sheathing material |
FRNC-compound HM1
|
| Colour of outer sheath |
orange
|
| Flame-retardant |
VDE 0482-266-2-4/IEC 60332-3-24 (Cat. C)
|
| Smoke density |
DIN EN 61034/IEC 61034
|
| Halogen-free |
DIN EN 50267/IEC 60754
|
| Fire-resistant |
VDE 0472-814/IEC 60331-11 (FE 180)
|
| Circuit integrity |
E90
|
| Max. temperature at conductor, °C |
90 °C
|
| Permitted outer cable temperature, fixed, °C |
-30 - +90 °C
|
| Permitted outer cable temperature, moved, °C |
-5 °C
|
| Bending radius, fixed installation, multicore |
12 x Ø
|
| Conductor shape |
round
|
| Colour of outer sheath |
orange
|
| metal base Cu |
0 EUR/100 kg
|
| Unit of measurement |
metre
|
Стандарты
For installation in dry and wet rooms, also for direct bedding in concrete, but not for direct burial in the ground and not for use in water. The cable has improved properties in case of fire and may be used in public buildings with high safety requirements. The cable is halogen-free, has a low smoke density and is fire-resistant according to VDE 0472 part 814 (180 min., = IEC 60331), EN 50200 and EN 50362. Furthermore the cable passed the test of 90 min. circuit integrity according to DIN 4102 part 12 (E 90) for all so-called standard installation systems (ladder, tray and ceiling). A special test certificate about the circuit integrity is issued by -The Civil Engineering Materials Testing Institute-. For calculation of electrical systems with circuit integrity has to be considered that electrical resistance of copper conductors at 1000 °C is approximately 4,5 times higher than at 20 °C and the current carrying capacity has to be reduced respectively.
| Артикул |
Типоразмер кабеля |
| 010951 |
(N)HXH-J E90 3X1.5 RE OG |
| 010952 |
(N)HXH-J E90 3X2.5 RE OG |
| 010953 |
(N)HXH-J E90 3X4 RE OG |
| 010954 |
(N)HXH-J E90 3X6 RE OG |
| 010955 |
(N)HXH-J E90 3X10 RE OG |
| 010956 |
(N)HXH-J E90 3X16 OG |
| 010957 |
(N)HXH-J E90 4X1.5 RE OG |
| 010958 |
(N)HXH-J E90 4X2.5 RE OG |
| 010959 |
(N)HXH-J E90 4X4 RE OG |
| 010960 |
(N)HXH-J E90 4X6 RE OG |
| 010961 |
(N)HXH-J E90 4X10 RE OG |
| 010962 |
(N)HXH-J E90 4X16 OG |
| 010963 |
(N)HXH-J E90 4X25 RM OG |
| 010964 |
(N)HXH-J E90 4X35 RM OG |
| 010965 |
(N)HXH-J E90 5X1.5 RE OG |
| 010966 |
(N)HXH-J E90 5X2.5 RE OG |
| 010967 |
(N)HXH-J E90 5X4 RE OG |
| 010968 |
(N)HXH-J E90 5X6 RE OG |
| 010969 |
(N)HXH-J E90 5X10 RE OG |
| 010970 |
(N)HXH-J E90 5X16 OG |
| 010971 |
(N)HXH-J E90 5X25 RM OG |
| 010989 |
(N)HXH-J E90 7X1.5 RE OG |
| 011020 |
(N)HXH-J E90 12X1.5 RE OG |
| 011124 |
(N)HXH-J E90 7X2.5 RE OG |
| 011162 |
(N)HXH-J E90 24X1.5 RE OG |
| 011177 |
(N)HXH-O E90 1X150 RM OG |
| 011178 |
(N)HXH-O E90 1X300 RM OG |
| 011744 |
(N)HXH-O E90 1X120 RM OG |
| 011754 |
(N)HXH-O E90 1X240 RM OG |
| 011755 |
(N)HXH-O E90 1X185 RM OG |
| 011756 |
(N)HXH-O E90 1X95 RM OG |
| 011757 |
(N)HXH-O E90 1X50 RM OG |
| 011843 |
(N)HXH-O E90 1X70 RM OG |
| 011869 |
(N)HXH-J E90 4X150 RM OG |
| 011949 |
(N)HXH-J E90 4X95 RM OG |
| 011950 |
(N)HXH-J E90 04X50 RM OG |
| 011955 |
(N)HXH-J E90 4X70 RM OG |
| 011956 |
(N)HXH-J E90 4X120 RM OG |
| 011963 |
(N)HXH-J E90 4X240 RM OG |
| 011982 |
(N)HXH-J E90 12X2.5 RE OG |
| 012011 |
(N)HXH-O E90 2X1.5 RE OG |
| 012020 |
(N)HXH-O E90 1X16 OG |
| 012021 |
(N)HXH-O E90 1X25 RM OG |
| 012022 |
(N)HXH-O E90 1X35 RM OG |
| 012221 |
(N)HXH-O E90 1X400 RM OG |
| 012928 |
(N)HXH-J E90 7X6 RE OG |
| 013128 |
(N)HXH-J E90 10X1.5 RE OG |
| 013223 |
(N)HXH-O E90 2X4 RE OG |
| 013224 |
(N)HXH-O E90 2X6 RE OG |
| 013225 |
(N)HXH-O E90 2X10 RE OG |
| 013226 |
(N)HXH-O E90 2X16 RE OG |
| 013293 |
(N)HXH-J E90 7X4 RE OG |
| 013666 |
(N)HXH-J E90 4X185 RM OG |
| 013667 |
(N)HXH-J E90 5X35 RM OG |
| 013668 |
(N)HXH-J E90 5X70 RM OG |
| 013669 |
(N)HXH-J E90 5X95 RM OG |
| 013670 |
(N)HXH-J E90 5X150 RM OG |
| 013671 |
(N)HXH-J E90 5X185 RM OG |
| 013885 |
(N)HXH-O E90 2X2.5 RE OG |
| 013912 |
(N)HXH-O E90 4X95 RM OG |
| 013913 |
(N)HXH-O E90 4X120 RM OG |
| 014073 |
(N)HXH-J E90 3X25 RM OG |
| 014074 |
(N)HXH-J E90 3X35 RM OG |
| 014075 |
(N)HXH-J E90 3X50 RM OG |
| 014076 |
(N)HXH-J E90 3X70 RM OG |
| 014077 |
(N)HXH-J E90 5X120 RM OG |
| 015730 |
(N)HXH-O E90 1X16 RM OG |