J-Y(St)Y ... Lg
Telecommunication cable J-Y(St)Y ... Lg
Использование
Preferably for telecommunication installations inside buildings in dry and humid rooms, but also for permanent installation at external walls if protected from sunlight. These cables are not approved for high-voltage applications.
Конструкция
| Customs Tariff Number (code number) |
85444991000000000
|
| CPR-classification according to EN 50575 |
Eca
|
| Standard |
VDE 0815
|
| Conductor material |
copper, bare
|
| Conductor construction |
Class 1 = solid
|
| Insulation |
PVC TI1
|
| Stranding unit |
Pair
|
| Stranding |
Layers
|
| Screen over strand |
Foil
|
| Drain wire |
yes
|
| Sheathing material |
PVC YM1
|
| Colour of outer sheath |
grey RAL 7032
|
| Flame-retardant |
VDE 0482-332-1-2/IEC 60332-1-2
|
| Permitted outer cable temperature, fixed, °C |
-30 - +70 °C
|
| Permitted outer cable temperature, moved, °C |
-5 - +50 °C
|
| Bending radius, fixed installation |
7.5 x Ø
|
| Bending radius, single bend |
2.5 x Ø
|
| Insulation resistance |
100 MOhmxkm
|
| Coupling K1 |
300 pF
|
| Core identification |
colours acc. to VDE 0815
|
| metal base Cu |
100 EUR/100 kg
|
| Unit of measurement |
metre
|
Стандарты
Preferably for telecommunication installations inside buildings in dry and humid rooms, but also for permanent installation at external walls if protected from sunlight. These cables are not approved for high-voltage applications.
| Артикул |
Типоразмер кабеля |
| 100001 |
J-Y(St)Y 1X2X0.6 GY |
| 100002 |
J-Y(St)Y 1X2X0.8 GY |
| 100003 |
J-Y(St)Y 2X2X0.6 GY |
| 100004 |
J-Y(St)Y 2X2X0.8 GY |
| 100005 |
J-Y(St)Y 3X2X0.6 GY |
| 100006 |
J-Y(St)Y 3X2X0.8 GY |
| 100007 |
J-Y(St)Y 4X2X0.6 GY |
| 100008 |
J-Y(St)Y 4X2X0.8 GY |
| 100009 |
J-Y(St)Y 5X2X0.6 GY |
| 100010 |
J-Y(St)Y 5X2X0.8 GY |
| 100011 |
J-Y(St)Y 6X2X0.6 GY |
| 100012 |
J-Y(St)Y 6X2X0.8 GY |
| 100013 |
J-Y(St)Y 8X2X0.6 GY |
| 100014 |
J-Y(St)Y 8X2X0.8 GY |
| 100015 |
J-Y(St)Y 100X2X0.6 GY |
| 100016 |
J-Y(St)Y 100X2X0.8 GY |
| 100017 |
J-Y(St)Y 10X2X0.6 GY |
| 100018 |
J-Y(St)Y 10X2X0.8 GY |
| 100019 |
J-Y(St)Y 12X2X0.6 GY |
| 100020 |
J-Y(St)Y 12X2X0.8 GY |
| 100021 |
J-Y(St)Y 14X2X0.6 GY |
| 100022 |
J-Y(St)Y 14X2X0.8 GY |
| 100023 |
J-Y(St)Y 16X2X0.6 GY |
| 100024 |
J-Y(St)Y 16X2X0.8 GY |
| 100025 |
J-Y(St)Y 20X2X0.6 GY |
| 100026 |
J-Y(St)Y 20X2X0.8 GY |
| 100027 |
J-Y(St)Y 24X2X0.6 GY |
| 100028 |
J-Y(St)Y 24X2X0.8 GY |
| 100029 |
J-Y(St)Y 30X2X0.6 GY |
| 100030 |
J-Y(St)Y 30X2X0.8 GY |
| 100031 |
J-Y(St)Y 40X2X0.6 GY |
| 100032 |
J-Y(St)Y 40X2X0.8 GY |
| 100033 |
J-Y(St)Y 50X2X0.6 GY |
| 100034 |
J-Y(St)Y 50X2X0.8 GY |
| 100035 |
J-Y(St)Y 60X2X0.6 GY |
| 100036 |
J-Y(St)Y 60X2X0.8 GY |
| 100037 |
J-Y(St)Y 80X2X0.6 GY |
| 100038 |
J-Y(St)Y 80X2X0.8 GY |