cable for festoon application (N)GRDCGOEU
cable for festoon application (N)GRDCGOEU
Использование
Screened Power and control cable for high mechanical requirements, frequently bendings in only one direction, especially for use in trolley systems on moving parts of machines and crans. Suitable for dry, humid and wet rooms and for outdoor use combined with specific EMC (electromagnetic compatibility) requirements.
Конструкция
| Customs Tariff Number (code number) |
85444995900000000
|
| Standard |
DIN VDE 0250-814 (with ref. to)
|
| Conductor material |
copper, bare
|
| Conductor construction |
Class 5 = flexible
|
| Insulation |
rubber 3GI3
|
| Material inner sheath |
rubber GM1b
|
| Screen |
tinned copper braid
|
| Screen coverage |
80 %
|
| Torsion |
+/- 90 °/m
|
| Sheathing material |
Gummi 5GM3
|
| Colour of outer sheath |
black
|
| Flame-retardant |
VDE 0482-332-1-2/IEC 60332-1-2
|
| UV-resistant |
yes
|
| Oil-resistant |
VDE 0473-811-404/IEC 60811-404
|
| Ozone-resistant |
VDE 0473-811-403/IEC 60811-403
|
| Max. temperature at conductor, °C |
90 °C
|
| Max. short circuit temperature at conductor, °C |
250 °C
|
| Permitted outer cable temperature, fixed, °C |
-50 - +80 °C
|
| Permitted outer cable temperature, moved, °C |
-30 - +80 °C
|
| Maximum tensile strength at the conductor |
15 N/mm²
|
| Operating speed festoon, m/min. |
240 m/min.
|
| metal base Cu |
150 EUR/100 kg
|
| Unit of measurement |
metre
|
Стандарты
Screened Power and control cable for high mechanical requirements, frequently bendings in only one direction, especially for use in trolley systems on moving parts of machines and crans. Suitable for dry, humid and wet rooms and for outdoor use combined with specific EMC (electromagnetic compatibility) requirements.
| Артикул |
Типоразмер кабеля |
| 053114 |
(N)GRDCGOEU-J 3X16 + 3G2.5 0.6/1 kV BK |
| 053116 |
(N)GRDCGOEU-J 3X35 + 3G6 0.6/1 kV BK |
| 053120 |
(N)GRDCGOEU-J 3X50 + 3G10 0.6/1 kV BK |